While keeping all the features of the Diva and the Full Break Out system the Diva Storm protects the building envelope from wind and projectiles produced from the dangerous hurricanes and tropical storms.
PERFORMANCE, COMFORT and SAFETY
- Digital control panel and self-controlled luminosity
- Incorporated traffic analyzer
- Infrared remote control
- Auto-control infrared barrier
- Locking device through infrared key
- Lighted display incorporated into the cover
- Airlock management...
The wide choice of finishes, leaves and glazing in many configurations let the architects create an entrance of their wishes and provide safer and more comfortable conditions for customers.
STANDARDS SPECIFICATIONS |
|
Number of moving leaves |
1 or 2 |
Casing Dimensions Standard / Reinforced |
6” x 8” / 7” x 8” |
Opening width min/max - door 1 leaf |
32” / 41” |
Opening width min/max - door 2 leaves |
32” / 83” |
Maximum opening height (Recommended) |
85” |
Maximum leaf weight |
1 x 330 lbs / 2 x 220 lbs |
Adjustable Opening speed |
4 to 39 in/s |
Adjustable Closing speed |
4 to 12 in/s |
Adjustable Opening time |
1 to 15 s |
Adjustable Opening force |
44 to 184 ft.lbs |
Adjustable Closing force |
44 to 110 ft.lbs |
Environment and electrical connections |
... |
Power supply |
Main 60 Hz, 120 V + 10 % with ground |
Power Consumption max / average |
500 W / 40W |
Standards |
... |
US |
ANSI 156.10, NFPA 101, UL |